YURA301 Flush diaphragm Pressure Transmitter

Renewable Energy for a Sustainable World.

YURA301 Flush diaphragm Pressure Transmitter

PCM1350 flush pressure transmitter is applicable to food, beverage, pharmaceutical and biological  engineering. Full metal flush-mounting isolation diaphragm is directly welded with process connection to ensure the precision connection between process connection and measuring diaphragm.

1 Overview

 

Therefore, no additional sealing gaskets are required, and it ensures there are no measurement dead zones. The stainless steel 316L diaphragm separates the measuring medium from the pressure sensor, and the process pressure from the diaphragm to the piezoresistive sensor is transferred statically through the filling fluid which has the hygienic license.

Notes:
1 Do not misuse documentation.
2 The information presented in this product sheet is for reference
only. Do not use this document as a product installation guide.
3 Complete installation, operation, and maintenance information is
provided in the instructions of the product.
4 Misuse of the product may cause danger or personal injury.

2 Product Feature

 

  • With SS316L isolation diaphragm structure
  • With high accuracy and all stainless steel structure 
  • With strong anti-interference and good stability 
  • Adjustable zero and span output 
  • With diversified form and structure, and easy for installation 
  • Multiple aseptic process connections available for process temperature up to 150℃

3 Application and Industries

 

  • Oil and gas, compressed air, steam, liquid, paste and powder media
  • Vacuum pressure detection such as vacuum transfer pump monitoring

Notes:
1 Do not touch the diaphragm with hard objects, which may cause damage to the diaphragm.
2 Please read the Instruction Manual of the product carefully before installation and
check the relevant information of the product.
3 Strictly follow the wiring method for wiring,
otherwise it may cause product damage or
other potential faults.
4 Misuse of the product may cause danger or
personal injury

4 Performance Parameter

 

Pressure range-100kPa…0~35kPa…2.5MPa
Pressure referenceGauge pressure, Absolute pressure, Sealed gauge pressure
Accuracy0.5%FS
Hysteresis0.1%FS
Repeatability0.1%FS
Temperature drift35kPa: ±3%FS (0℃~60℃)
 Other ranges: ±1.5%FS (-10℃~70℃)
Response time≤1ms(Up to 90%FS)
OverpressureRefer to the range selection table
Service life≥1×106 pressure cycles
Ambient temp.-20℃~85℃
Performance parameters (cont.)
Medium temp.-30℃~125℃
Storage temp.-40℃~125℃
EMCImmunity: IEC 61000-6-2, Radiation: IEC 61000-6-3
Insulation resistance≥100MΩ/250VDC

Vibration

performance

Sine curve: 20g, 25Hz~2kHz; IEC 60068-2-6

Random: 7.5grms, 5Hz~1kHz; IEC 60068-2-64

Protection gradeIP67 (No connectors are included.)
SurgeIEC 61000-4-5 3 level
Voltage resistance

Current output:500V/AC 1min

Voltage output:250V/AC 1min

Static electricityIEC 61000-4-2 4 level
Medium compatibilityAll medium compatible with 316L
Ex-proofIntrinsically safe explosion-proof ExiaⅡCT6 (Only for 4 to 20mA output)
Net weight300~350g
Output and power supply
CodeB1B7Customizable
Output4~20mA0~10V 
Power supply12~30VDC12~30VDC 

 

Scroll to Top